The Denagene Tajhiz Eco Drop is an economical UV-Vis microvolume spectrophotometer for measuring the concentration and purity of DNA, RNA, and proteins. It reports sample quality within seconds using 1–2 µL of sample and without requiring cuvettes.
Functionally, Eco Drop follows the standard NanoDrop workflow: the sample is placed on the pedestal, a liquid column forms in the optical path, and the system enables spectral measurement by automatically adjusting the pathlength from 1.0 to 0.2 mm. Spectral acquisition and analysis are performed using a 3648-element linear CCD array.
Eco Drop’s main advantage is its LED light source, providing lower power consumption, long lifetime, and more economical maintenance. For this reason, Eco Drop is well suited for laboratories that need a dependable NanoDrop for routine daily QC.
Key Technical Specifications (Eco Drop)
- Light source: LED
- Sample volume: 1–2 µL (cuvette-free)
- Optical pathlength: 1.0 mm with auto-ranging down to 0.2 mm
- Wavelength range: 260–280 nm and 360–600 nm
- Wavelength accuracy: < 0.7 nm
- Spectral resolution: 2.5 nm (FWHM at 546 nm)
- Absorbance precision: 0.003 Abs
- 10 mm-equivalent absorbance range: 0.02–75 Abs
- dsDNA limit of detection: 2 ng/µL
- Maximum dsDNA concentration: 3700 ng/µL
- Measurement cycle time: ~10 seconds
- Dimensions / weight: 25 × 25 × 25 cm / 3.5 kg
- Pedestal material: 303 stainless steel and quartz fiber
- Power: 220 V, 50 Hz / ~30 W
Advantages vs. Conventional Spectrophotometers
- Ultra-low sample volume (1–2 µL) with no cuvette requirement
- Fast and simple QC before sensitive steps (PCR/qPCR, etc.)
- More economical than higher-end models, ideal for routine use
- LED light source with low power consumption and long lifetime
- Reduced human error from extensive sample preparation and repeated dilutions
Eco Drop Applications in Molecular & Diagnostic Laboratories
- Measuring DNA/RNA concentration after extraction and before PCR
- RNA QC prior to RT-PCR and gene expression assays
- Checking samples for genetics, cloning, and academic research projects
- Rapid evaluation of proteins and UV-Vis solutions
- Suitable for PCR labs, molecular labs, research labs, and training/teaching laboratories
Eco Drop Maintenance & Calibration
- Clean the pedestal after each sample using a lint-free tissue and distilled water/ethanol
- Perform proper blanking using the same buffer/solvent as the sample
- Prevent exposure to dust and humidity; keep the device on a stable surface
- Perform periodic calibration according to laboratory standards and company recommendations
Buying Guide for Denagene Tajhiz NanoDrop (Eco Drop vs. Pro Drop)
Before choosing between Eco Drop and Pro Drop, consider:
- Daily workload: a higher number of samples makes speed and measurement stability more important
- Application type: DNA/RNA only, or also proteins and OD600?
- Need for higher accuracy and speed: Pro Drop (xenon flash lamp) is better for users sensitive to accuracy and repeatability
- Data storage and export: USB output and connectivity simplify documentation and reporting
Denagene Tajhiz experts can recommend the best option (Eco Drop or Pro Drop) based on your test types, sample volume, and budget. In-country installation, training, support, and periodic calibration services are also available.
After-Sales Service
- Warranty: 12 months official warranty
- After-sales support: spare parts supply and servicing for several years after purchase
- On-site installation and commissioning
- Full user training for personnel
- Optional periodic calibration services
Technical Specification
| Specification |
Eco Drop |
Pro Drop |
| Light source |
LED |
Xenon flash lamp |
| Sample volume (µL) |
1–2 |
1–2 |
| Optical pathlength (mm) |
1.0 (auto-ranging down to 0.2) |
1.0 (auto-ranging down to 0.2) |
| Detector |
3648-element linear silicon CCD array |
3648-element linear silicon CCD array |
| Wavelength range (nm) |
260–280 and 360–600 |
220–700 |
| Wavelength accuracy (nm) |
< 0.7 |
< 0.7 |
| Spectral resolution (FWHM at 546 nm) |
2.5 nm |
2.5 nm |
| Absorbance precision (1 mm path) |
0.003 Abs |
0.003 Abs |
| Absorbance accuracy (at Abs 0.76, 257 nm) |
2% |
2% |
| Absorbance range (10 mm equivalent) |
0.02–75 Abs |
0.02–75 Abs |
| dsDNA limit of detection |
2 ng/µL |
2 ng/µL |
| Max dsDNA concentration |
3700 ng/µL |
3700 ng/µL |
| Measurement cycle time (s) |
10 |
2 |
| Dimensions (cm) |
25 × 25 × 25 |
25 × 25 × 25 |
| Weight (kg) |
3.5 |
3.5 |
| Pedestal material |
303 stainless steel & quartz fiber |
303 stainless steel & quartz fiber |
| Operating voltage |
220 V, 50 Hz |
220 V, 50 Hz |
| Power consumption (W) |
30 |
30 |